XFOR: OV/VM Connector Returns Different NDRs to PROFS Sender
ID: Q188819
 
 |  The information in this article applies to:
 
 
Microsoft Exchange Server, versions  5.0, 5.5
 
 
 SYMPTOMS
Messages sent from PROFS to unknown PROFS addresses in Exchange using the
LinkAge version 3.2 Connector or the Microsoft Exchange Connector for IBM
OV/VM version 5.5 may result in different types of non-delivery reports
(NDRs) being returned.
 Address Space on OV/VM Connector in Site 1:
+-----------------+
|      PROFS      |
|                 |
|   NODE3(USER3)  |
+--------+--------+
         |
         | OV/VM Connector
         |
+--------+--------+                +-----------------+
| Exchange Site 1 | X.400 Connector| Exchange Site 2 |
|                 +----------------+                 |
|   NODE1(USER1)  |  with Dir Rep  |   NODE2(USER2)  |
+-----------------+                +-----------------+ 
 Address Space on X.400 Connector in Site 1:
      PROFS * cost=1 
 NOTE: This particular Address Space is not
required to reproduce the NDR behavior.
      PROFS NODE2(*) cost=1 
 
 Address Space on X.400 Connector in Site 2:
 
      PROFS * cost=1 
 Messages sent from a PROFS user to an unknown PROFS address in Site 1
   result in an NDR similar to the following:
The conditions leading to the production of this NDR are explained in
   the CAUSE section (1), below.
      BADUSER unknown at NODE1; <date and time> not received.
 
 Messages sent from a PROFS user to an unknown PROFS address in Site 2
   result in a different NDR message:
This NDR does not indicate that the PROFS address was unknown. The
   conditions leading to the production of this NDR are explained in the
   CAUSE section (2), below.
      NODE2 cannot deliver <date and time> to BADUSER.
 
 
 CAUSE
This behavior is by design. The reason for the differences in the NDR
messages is that the delivery error is detected at different points in the
mail network. Depending upon the location in the network, where the problem
is detected, and the circumstances under which it is detected, the NDR is
created. It is not possible or desirable to guarantee the same error
message for different "bad recipients."
 A fundamental function of the connectors (PROFS, SNADS, and Notes) is to
allow the use of Exchange as a messaging backbone. As part of this feature,
it is not required that every address in every attached messaging system be
registered in the Exchange directory adjacent to the connector. In fact,
Exchange administrators may decide, for various reasons, not to enable
directory synchronization (dirsync) between Exchange and PROFS. However,
even if dirsync is enabled, directory replication latency may cause a valid
address not to be immediately present in a directory.
 
 
 When a PROFS user sends an address to NODE1 (BADUSER) in the topology
   shown above, the connector determines that NODE1 is the PROFS proxy node
   name by reading the site addressing. The connector categorically knows
   that all proxy addresses with the node name of NODE1 must be registered
   in Site 1's Exchange directory. When the address lookup fails, the
   connector knows the user does not exist and immediately generates the
   appropriate error code for an unknown address NDR.
 When a PROFS user sends an address to NODE2(BADUSER), the connector
   knows that NODE2 is not the PROFS proxy node name for the immediate
   site. Because NODE2(BADUSER) cannot be found in Site 1's directory, the
   message is submitted to the Exchange backbone for routing.
 
 If there is a specific NODE2(*) PROFS Address Space defined on the X.400
   Connector leading to Site 2, the message transfer agent (MTA) routes the
   message to the other Site, where the receiving MTA attempts to resolve
   the address. If the address does not exist in Site 2's directory, the
   MTA once again routes the message, based on Site 2's GWART. Site 2 has a
   PROFS * Address Space defined on the X.400 Connector, which causes the
   MTA to route the message back to Site 1. The MTA in Site 1 eventually
   routes the message back to the OV/VM Connector based on the PROFS *
   Address Space defined on the OV/VM Connector. The OV/VM Connector
   detects that the message is looping and generates the error code that
   causes the following NDR to be generated:
The looping message condition is detected even more quickly when the
   PROFS * Address Space defined on the OV/VM Connector is the only PROFS
   Address Space defined in Site 1.
      NODE2 cannot deliver <date and time> to BADUSER.
 
 Additional query words: 
 
Keywords          : XFOR Version           : winnt:5.0,5.5
 Platform          : winnt
 Issue type        : kbprb
 |