The information in this article applies to:
SUMMARY
When the Exchange Database Engine encounters a read verification failure, referred to as an -1018 error, (in accordance with Knowledge Base article Q151789, XADM: Error -1018 (JET_errReadVerifyFailure)), it will now retry to successfully read the page a maximum of 16 times. This is a new feature of the Exchange Database Engine, referred to as "ESE," and was introduced in build 5.5.2395.0 of Ese.dll.
MORE INFORMATION
Retry operations will occur when running ESEUTIL in either Repair (/P) or Integrity Check (/G) modes using a build of Ese.dll between 5.5.2395.0 and (but not including) 5.5.2416.0.
Q197060 XADM: JET Retry Hotfix Makes Repair (ESEUTIL /P) Very Slow Additional query words: jet re-read sixteen
Keywords : |
Last Reviewed: March 11, 1999 © 2000 Microsoft Corporation. All rights reserved. Terms of Use. |