BUG: Redirection of Input to a Spawned PowerStation App Fails

ID: Q106723


The information in this article applies to:
  • Microsoft FORTRAN PowerStation for MS-DOS, versions 1.0, 1.0a


SYMPTOMS

PowerStation applications spawned with either SYSTEMQQ or RUNQQ hang when input is redirected from a file. Also, the input is split and directed at both the application and the console.


CAUSE

The MS-DOS extender that comes with PowerStation does not handle console input the same way as MS-DOS does. The hang occurs because the spawned application is waiting for an end-of-file (EOF).


STATUS

Microsoft has confirmed this to be a problem in FORTRAN PowerStation version 1.0 and version 1.0a for MS-DOS.

This is not a problem in FORTRAN PowerStation 32.


MORE INFORMATION

Applications that are not MS-DOS extended handle redirection input incorrectly when spawned with RUNQQ or SYSTEMQQ.

To demonstrate the problem, follow these steps:

  1. Copy both sample programs into the same directory.


  2. Compile both TEST.FOR and B.FOR with FORTRAN PowerStation 1.0 for MS-DOS.


  3. Run TEST.EXE.


Sample Code #1 (TEST.FOR)


C No compiler options required
      include 'flib.fi'
      include 'flib.fd'
      if(.not.SystemQQ('b < test.for')) print*, 'systemqq failed'
      end 

Sample Code #2 (B.FOR)


C No compiler options required
      character*20 c
      ierr = 0
      do while(ierr.ne.-1)
        read(*,"(a)",iostat=ierr) c
        print*, c
      end do
      end 

Additional query words: nofpsnt 1.00

Keywords :
Version : :1.0,1.0a
Platform :
Issue type :


Last Reviewed: November 1, 1999
© 2000 Microsoft Corporation. All rights reserved. Terms of Use.