The information in this article applies to:
SYMPTOMSA program that contains a simple arithmetic expression including constant out of range may produce incorrect results. Using the -4Yb compiler option does not give a run-time error on constants that are out of range even though it should. CAUSEThe constant folding algorithm (arithmetic performed at compile time) generates 0 (zero) for the variable out of range. RESOLUTIONAvoid using a simple constant expression that might be out of range. Use the temporary variable for the intermediate results and then use this variable in the expression. Compile the program with -4Yb and the appropriate run-time error will be generated. STATUSMicrosoft has confirmed this to be a problem in Microsoft FORTRAN PowerStation 32 for NT, version 1.0 and FORTRAN Powerstation for MS-DOS version 1.0 and 1.0a. This is not a problem in Microsoft FORTRAN for MS-DOS, version 5.1, or FORTRAN PowerStation 32, version 4.0. MORE INFORMATIONSample Code #1
Sample Code #2
Additional query words: 1.00 runtime run time
Keywords : kbCompiler kbFL32 kbFortranPS |
Last Reviewed: November 1, 1999 © 2000 Microsoft Corporation. All rights reserved. Terms of Use. |