SUMMARY
When debugging a function with FORTRAN PowerStation, it can be useful to
view the return value of the function. In FORTRAN, this variable has the
same name as the function. Because of this, typing the name of this
variable into the Watch window displays the address of the function, not
the return value. This article details how to view the return value inside
the function. Note that the main text of this article discusses only the
default FORTRAN calling conventions; the article does not cover C VARARGS
or other such function calling conventions. If you want to use these
conventions, a method for viewing the return variable is discussed at the
end of this article.
NOTE: In Fortran PowerStation 4.0 it is now possible to view a function's
return value in the watch window. When you type in the name of the
function in the watch window, instead of the function's address you
get the actual function return value.
MORE INFORMATION
First, consider an INTEGER function. After stepping into the function and
stepping past the function prolog (the first line of the function--in mixed
mode, the series of PUSH instructions), the base register EBP points to the
start of storage for the return value. Because this is stack-based storage,
the memory address for an integer return value would have address EBP-4.
Once the function is completed, the return value is stored in the EAX
register where the function caller can view it.
As an example, build a program with an INTEGER*4 FUNCTION, and step into
the function. If you step past the prolog and type "EBP-4,x" in the Watch
window, you will see the hexadecimal address of the local storage for the
return value. To view the actual value, bring up the memory window at the
given address, using INTEGER*4 formatting. The value next to the address is
the actual current value of the function's return value. You can view this
throughout the function call. Upon return to the caller, you can see the
return value in the EAX field in the Registers window. Note that this will
be the hexadecimal representation of the integer.
If you want to view the actual value, you can use the Watch window to
convert this for you. For example, if the EAX register reads FFFFFFFF, type
in "#ffffffff,d" to display a hexadecimal # in decimal form. The actual
value, -1, will be printed.
For all INTEGER functions, the return value is stored in EBP-4, regardless
of the size of the integer. For INTEGER*2 functions, the value is returned
to the caller in the AX register, the low-order word of the EAX register.
For INTEGER*1 functions, the caller receives the value in AL, the low-order
byte of EAX.
LOGICAL variables work exactly the same as INTEGER variables of the same
size. Use the same method, with the memory window formatted to view the
type of the function. CHARACTER (BYTE) variables work exactly the same as
INTEGER*1 values.
REAL values are handled slightly differently. For REAL*4 variables, the
return value is again stored at EBP-4. To return the value to the function,
however, the value is pushed onto the floating-point stack. This stack is
viewable from the Registers window. When you step out of the function, the
value is moved onto the stack. Upon return from the function call, the
caller then pops this value off the stack. By viewing the changed
(highlighted) elements in the FP stack, you can see the returned value.
REAL*8 values are also returned to the caller on the FP stack, but the
local storage within the function is at EBP-8. Again, use the memory window
to format the values at these addresses in order to see the actual return
value.
COMPLEX numbers work somewhat differently. They are handled as structures
of two REAL numbers. When a structure is to be returned from a function,
the caller allocates space in its current stack for the structure. A
pointer to this location is pushed onto the stack as part of the function
call. In the function, this pointer is stored at location EBP+8. You can
find the pointer value stored here by viewing location EBP+8 in the memory
window. The first 4 bytes here are the address. Note that the address is
stored in the processor's internal byte ordering. For example, if the 4
bytes read as 98 FF 14 00, the actual address would be #0014FF98. You can
then enter this address into the memory window and view the bytes in the
string. Upon return from the function, the value will be in this location,
and the value will be copied from this temporary storage to the variable
that receives the return value.
The same method is also used for all STRUCTURE types. Note that to see the
actual elements in the structure formatted in their base type, you must
change the formatting of the memory window and find the offset of the
structure member in the structure. In this case, it may be easier to view
the structure in BYTE format, and do the appropriate translations by hand.
This process can also help you to determine the size requirements of your
structures, and view the underlying memory usage of your program.
Finally, CHARACTER return values are dealt with in the same way as COMPLEX
and STRUCTURE arguments. A buffer is pointed to by EBP+8, which is used to
store the CHARACTER data. Note that at EBP+12 you can also see the value of
an INTEGER*4 value, which indicates the size of the CHARACTER value. This
can be useful in tracking problems with large CHARACTER variables.
If you want to view the return value from a function that does not use the
standard FORTRAN calling convention, you can use the Mixed Source/Assembly
mode to determine the value that is being used to store the return value.
Find a line of code that sets the return value. The last few assembly
instructions for this line will be the code that stores the value. The
address used to store the return value can then be found and entered into
the memory window, just as it was done in the previous examples.
Additional query words:
kbinf 1.00
Keywords : kbDebug kbide
Version : :1.0
Platform : NT WINDOWS
Issue type :