UNCONF: PRB: Error in SCX: Objtype=1 not found

ID: Q125418

2.5x 2.60 2.60a MS-DOS

  kbprb

*****************************************************************
**                          - WARNING -                        **
**    THE INFORMATION BELOW IS PRELIMINARY AND HAS NOT BEEN    **
**    CONFIRMED, EDITED OR TESTED BY MICROSOFT.  USE ONLY      **
**    WITH DISCRETION.                                         **
*****************************************************************

WARNING: The information in this article has not been confirmed or tested by Microsoft. Some or all of the information in this article has been taken from unconfirmed customer reports. ANY USE BY YOU OF THE INFORMATION PROVIDED IN THIS ARTICLE IS AT YOUR OWN RISK. Microsoft provides this information "as is" without warranty of any kind, either expressed or implied, including but not limited to the implied warranties of merchantability and/or fitness for a particular purpose.

The information in this article applies to:

  • Microsoft FoxPro for MS-DOS, versions 2.5x, 2.6, 2.6a

SYMPTOMS

When generating a screen in the screen wizard, the following error message is displayed:

   Error in SCX: Objtype=1 Not Found
   Genscrn Line Number: xx
   Press any key to clean up and exit (or something equivalent)

CAUSE

The _GENSCRN system memory variable is not set to the default GENSCRN.PRG program provided with FoxPro.

RESOLUTION

Reset _GENSCRN to the Foxpro default GENSCRN.PRG program, and then recompile the screen(s).

MORE INFORMATION

This problem has been reported to occur under the following circumstances:

  • The _GENSCRN variable is set to a network directory containing the GENSCRN.PRG program from a different version of FoxPro.

    -or-

  • The _GENSCRN variable is set to Software Business Technology (SBT) Corporation's GENSCRN.PRG program.

SBT accounting applications by SBT Corporation are manufactured independent of Microsoft. Microsoft makes no warranty, implied or otherwise, regarding these products' performance or reliability.

For more information contact:

   SBT Corporation
   One Harbor Dr.
   Suite 300
   Sausalito, CA  94965
   Phone: 415-331-9900
   Fax:   415-331-1951

Additional reference words: UNCONFIRMED Genscrn Objtype 2.50 2.50a 2.50b 2.60a Third-party 3rd party accounting
KBCategory:   kbprb
KBSubcategory: FxtoolSbuilder
Keywords          : kb3rdparty kberrmsg FxtoolSbuilder 
Version           : 2.5x 2.60 2.60a
Platform          : MS-DOS


Last Reviewed: May 22, 1998
© 2000 Microsoft Corporation. All rights reserved. Terms of Use.