FIX: Error Type 11 When Using PowerMac and Reopening a QueryID: Q125519 2.60a MACINTOSH The information in this article applies to:
SYMPTOMSWhen using the Macintosh PowerPC and opening a query built from the RQBE with certain criteria selected, you receive this error:
You then have to click the Restart button or press the reset button to
regain control of the computer. This happens only with the PowerPC using
version 7.0 or later of the Macintosh System software.
CAUSEThis problem appears to be caused by criteria in the RQBE that chooses a character field in the Field Name box under Selection Criteria and uses NOT IN as the operator with six to eight constants separated by commas and typed in the Example Box. The number of characters per constant may also be a factor. If a smaller number of constants are used, the error might not happen.
RESOLUTIONTo work around this problem, add another statement to the Selection Criteria of the same field type, and place smaller increments of what you included in the first Selection Criteria statement. It seems that any number over three or four items causes the error. It might take several Statements to get the number of items down to three or four per line in the Example box.
STATUSMicrosoft has confirmed this to be a problem in the Microsoft products listed at the beginning of this article. This problem was fixed in Microsoft Visual FoxPro for Macintosh version 3.0b.
MORE INFORMATION
Steps To Reproduce Problem1. Open the Customer database in the FPM26:TUTORIAL folder. 2. Open the RQBE by clicking the RUN option on the menu bar and selecting 3. Click the Order By check box and add Customer.state to the Ordering
4. Under the Selection Criteria section, choose Customer.state in the Field
5. Click the NOT box, and choose IN located in the list box beside the NOT
6. In the Example box, type:
7. Save the query by holding down the Control key and pressing the W key.
8. Click FILE, OPEN on the menu bar, and change the TYPE: popup to Query.
Upon opening the query, FoxPro will crash, giving the above mentioned error
message. This error will not occur when fewer than five constants are in
the Example field. If each constant contains more letters, the system may
crash with even fewer constants in the Example box.