BUG: Print Preview Toolbar May Be Off Screen

ID: Q135801


The information in this article applies to:
  • Microsoft Visual FoxPro for Windows, versions 3.0, 3.0b, 5.0, 5.0a, 6.0


SYMPTOMS

The print preview toolbar may only be partially viewable if you have a toolbar, such as the Standard toolbar, docked at the top of the screen, and only a small amount of space exists to the right of the already docked toolbar. The Print Preview toolbar continues off the screen to the right.

If you zoom the following items to full screen, the title bar of the window disappears, the Close button appears to the left of the File Menu, and the Zoom button appears to the right of the Help Menu. This happens when you zoom the following windows:

  • Print Preview window for Reports/Labels.


  • The editing window for the Report, Label, Form, Program, or Class Browser



CAUSE

When Visual FoxPro requests a dock to the top of the window, the toolbar manager should determine if it will fit on the current row, and if not, it should open up a new row. Currently, however, the toolbar manager will only open up a new row if none of the new toolbar will be visible.


RESOLUTION

Undock the Print Preview toolbar and close the report by clicking the Close button on the toolbar. The next time you preview the report, the Print Preview toolbar will appear in the previous undocked location.

As an alternative, you can close or undock all other toolbars before doing a Print Preview of the report.


STATUS

Microsoft has confirmed this to be a problem in the Microsoft products listed at the beginning of this article. We are researching this problem and will post new information here in the Microsoft Knowledge Base as it becomes available.

Additional query words: vga video kbvfp300 kbvfp500 kbvfp600

Keywords : kbVFp kbVFp300bbug kbVFp500bug buglist3.00 FxtoolFormdes
Version : WINDOWS: 3.0,3.0b,5.0,6.0
Platform : WINDOWS
Issue type : kbbug


Last Reviewed: August 16, 1999