PRB: "Error Locating Config File-Bad Path?" in VFP 5.0

ID: Q163801


The information in this article applies to:
  • Microsoft FoxPro for Windows, version 2.0x
  • Microsoft Visual FoxPro for Windows, versions 3.0, 3.0b, 5.0, 5.0a, 6.0


SYMPTOMS

When starting Visual FoxPro, the following error can occur:

"Error locating config file-bad path?"
If starting FoxPro for Windows 2.x, the error will be:
"Invalid path or file name".
After clicking OK, Visual FoxPro starts and runs properly. FoxPro for Windows 2.x will not run, and terminates with a General Protection Fault. When starting an executable file built by any of the FoxPro products listed above, one or more of the following errors can occur:
Error locating config file-bad path?
Invalid path or file name
A DO dialog box appears
If the .exe file was created in FoxPro for Windows 2.x or Visual FoxPro 3.0, a general protection fault can occur after the above errors appear.


CAUSE

This error message is by design. The problem is the contents of the PATH environment variable. The error is most commonly caused by a missing semicolon, which divides the directories that make up the Path statement. Other errors in the PATH may also cause the error.


RESOLUTION

Edit the Path statement and add the semicolon. If the operating system is Windows 3.1, Windows 95 or Windows 98, the Path statement will be found in the Autoexec.bat file. If the operating system is Windows NT, go to the System icon in the Control Panel. In Windows NT 4.0, after you open the System icon, select the Environment tab then check the contents of the Path variable. Windows NT also reads an Autoexec.bat file if one is present. Look for a SET PATH statement in the Autoexec.bat file if the Environment tab Path variable does not contain any visible problems. Other types of batch files or login scripts may also reset the path. You can view the current path by opening a command prompt and typing SET PATH.


STATUS

This behavior is by design.


MORE INFORMATION

When FoxPro or an executable file built with FoxPro starts, it looks for a Config.fpw file in the home directory. If there is not a Config.fpw file located there, it looks along the Path statement. If there is a semicolon missing that separates the directories in the path, one or more of the above errors occurs because FoxPro cannot continue looking along the path to locate the Config.fpw file. There can be an old directory in the path statement that no longer exists on the computer and FoxPro ignores it and continues looking in the next directory of the path. If no Config.fpw file is found, FoxPro starts without one.

Steps to Reproduce Behavior

  1. Modify the Path statement and remove one of the semicolons that separates the directories.


  2. Restart the computer for the changes to take effect.


  3. Start FoxPro or an .exe file to receive one or more of the errors listed above.


Additional query words:

Keywords : kbenv kbVFp FoxWin FxenvAutoexec
Version : WINDOWS:2.0x,3.0,3.0b,5.0,5.0a,6.0
Platform : WINDOWS
Issue type : kbprb


Last Reviewed: June 21, 1999
© 2000 Microsoft Corporation. All rights reserved. Terms of Use.