FIX: Project Manager Not Refreshed Correctly After Build

ID: Q221698


The information in this article applies to:
  • Microsoft Visual FoxPro for Windows, version 6.0


SYMPTOMS

The Document and Class tabs in the Project Manager might not refresh properly after building a project, application, or executable.


RESOLUTION

Try one of the following to resolve this problem:

  • Close down the Project Manager and then re-open it.


  • Upgrade to Visual Studio 6.0 Service Pack 3.



  • STATUS

    Microsoft has confirmed this to be a bug in the Microsoft products listed at the beginning of this article.

    This bug was corrected in Visual Studio 6.0 Service Pack 3.

    For more information about Visual Studio service packs, please see the following articles in the Microsoft Knowledge Base:

    Q194022 INFO: Visual Studio 6.0 Service Packs, What, Where, Why

    Q194295 HOWTO: Tell That Visual Studio 6.0 Service Packs Are Installed


    MORE INFORMATION

    Steps to Reproduce Behavior

    1. Open the Tastrade project.


    2. Select the Document tab, then click the Build button.


    3. Select the Build Application button, then click OK.


    4. Once the build application is completed, toggle back and forth between the Document and Class tabs. The content does not refresh correctly on either tab .

    Additional query words:

    Keywords : kbProjManager kbVFp600 kbVS600sp3fix kbGrpFox kbDSupport
    Version : WINDOWS:6.0
    Platform : WINDOWS
    Issue type : kbbug


    Last Reviewed: July 8, 1999