Err Msg: Cannot Start Communications with the Desktop...
ID: Q161446
|
The information in this article applies to:
-
Microsoft Windows CE version 1.0 for the Handheld PC
SYMPTOMS
When you try to connect your Handheld PC (H/PC) to your desktop computer
using H/PC Explorer, you may receive the following error message:
Cannot start communications with the desktop computer. Remote
Networking could not start due to a critical error (Error 754).
Please reconnect the H/PC. If the problem persists, restart the
H/PC using the instructions provided by the manufacturer.
CAUSE
This behavior occurs when your H/PC has low program memory.
RESOLUTION
Adjust the memory settings on your H/PC. To do so, follow these steps:
- Tap the Start button, tap Settings, and then double-tap System.
- Tap the Memory tab, move the slider to the left to increase available
program memory, and then tap OK.
- If there is a limited amount of memory available, you may need to reset
your H/PC to free additional memory. When you reset your H/PC, any
unsaved data is lost.