Err Msg: Cannot Start Communications with the Desktop...

ID: Q161446


The information in this article applies to:
  • Microsoft Windows CE version 1.0 for the Handheld PC


SYMPTOMS

When you try to connect your Handheld PC (H/PC) to your desktop computer using H/PC Explorer, you may receive the following error message:

Cannot start communications with the desktop computer. Remote Networking could not start due to a critical error (Error 754). Please reconnect the H/PC. If the problem persists, restart the H/PC using the instructions provided by the manufacturer.


CAUSE

This behavior occurs when your H/PC has low program memory.


RESOLUTION

Adjust the memory settings on your H/PC. To do so, follow these steps:

  1. Tap the Start button, tap Settings, and then double-tap System.


  2. Tap the Memory tab, move the slider to the left to increase available program memory, and then tap OK.


  3. If there is a limited amount of memory available, you may need to reset your H/PC to free additional memory. When you reset your H/PC, any unsaved data is lost.


Additional query words: hand held

Keywords : kbenv kberrmsg wince handheld
Version : WINDOWS:1.0
Platform : WINDOWS
Issue type :


Last Reviewed: September 1, 1999
© 2000 Microsoft Corporation. All rights reserved. Terms of Use.