Uninstalling IntelliType 1.0 from Windows 3.x or WFWG 3.x
ID: Q121124
|
The information in this article applies to:
-
Microsoft IntelliType software version 1.0
SUMMARY
This article discusses how to remove the Microsoft IntelliType software
version 1.0 from Microsoft Windows or Windows for Workgroups. The text
below was taken from the IntelliType README.TXT file.
MORE INFORMATION
The Help topic on uninstalling the Microsoft Natural Keyboard software is
incomplete. To return your system to its previous condition before you ran
the Microsoft Natural Keyboard Setup program, follow the procedures below.
- Delete all files in the C:\MSINPUT\KEYBOARD directory (or
whatever target directory you specified during setup). If
\KEYBOARD is the only subdirectory, you can delete the \MSINPUT
directory as well. If there are other subdirectories,
indicating that other input device software (such as a mouse)
is installed in \MSINPUT, do NOT delete the directory.
- Delete the files TASKSW16.EXE and TASKMAN.HLP from your Windows
directory.
- Delete the IntelliType Manager, Task Manager, and IntelliType
Readme icons from the Microsoft Input Devices program group.
(Single-click on the icon and press DELETE.) If the program
group is empty, you can delete it also.
- Open the SYSTEM.INI file (located in your Windows directory)
and edit the following entries so they read as shown:
[boot]
keyboard.drv=keyboard.drv
taskman.exe=taskman.exe
[keyboard]
keyboard.dll=
oemansi.bin=
type=4
- In the SYSTEM.INI file, delete the following line from
the [keyboard] section:
SubType=8
- In the SYSTEM.INI file, edit the following value so it reads as
shown if there are no other Microsoft input devices installed:
[386Enh]
Keyboard=*vkd
Do NOT change this setting if there are other Microsoft
input devices installed.
- If there are no other Microsoft input devices installed,
delete "C:\MSINPUT\POINTER.EXE" from the "load=" line in
the [windows] section of the WIN.INI file. Do NOT remove
this value or any other values for this setting if there
are other Microsoft input devices installed.
- Open the CONTROL.INI file. Remove the line
mskbd=c:\MSINPUT\KEYBOARD\kbd16.cpl
from the [MMCPL] section and remove the entire [Don't Load]
section.
- Open the AUTOEXEC.BAT file and delete the following line:
c:\msinput\keyboard\kbdcpl.exe /s
- Reboot Microsoft Windows to reinitialize your settings.
Additional query words:
3.00 3.10 3.11 uninstall remove
Keywords : mnk wfwg
Version : WINDOWS:1.0
Platform : WINDOWS
Issue type :
|