Internet Explorer 5 Readme.sun.txt File
ID: Q222563
|
The information in this article applies to:
-
Microsoft Internet Explorer version 5 for UNIX on Sun Solaris
SUMMARY
This article contains a copy of the Readme.sun.txt file included with Internet Explorer 5 for Solaris with Outlook Express.
MORE INFORMATION
----------------------------------
README
Internet Explorer 5 for Solaris
with Outlook Express
February 2, 1999
----------------------------------
Copyright (c) Microsoft Corporation, 1995-1999
The readme for your version of Internet Explorer for UNIX is named
readme.<PLATFORM>.txt, where PLATFORM refers to sun, hp, etc.
This document provides the information you need to get started and
late-breaking information to supplement the product documentation.
========
CONTENTS
========
SYSTEM REQUIREMENTS
SETUP
Downloading Internet Explorer 5
Installing Internet Explorer 5
Uninstalling Internet Explorer 5
CUSTOM PACKAGING VIA THE IEAK
KNOWN ISSUES
Solaris Compatibility
Solaris 2.4 and below
Solaris 2.5
Ultra 5's and 10's
Miscellaneous
Internet Explorer User Interface Issues
Outlook Express Issues
IEAK Issues
Miscellaneous Issues
USER AGENT
USING JAVA
Java Packaging via the IEAK
COMMON DESKTOP ENVIRONMENT INTEGRATION
AN ALTERNATE WAY TO ORGANIZE FAVORITES
NTLM DOMAIN AUTHENTICATION
SUPPORT
===================
SYSTEM REQUIREMENTS
===================
To run the released version of Internet Explorer 5 for Solaris, your
system must meet the following minimum requirements:
* A Sparcstation 2 or greater
* English Solaris 2.5 and above
* 32 MB of RAM (64 MB recommended)
* 68 MB of hard-disk space to perform the installation
=====
SETUP
=====
Downloading Internet Explorer 5
---------------------------------
You can download Internet Explorer 5 from the following HTTP and FTP
sites:
http://www.microsoft.com/unix/ie/
ftp://ftp.microsoft.com/deskapps/ie/unix/sol/ie5
The file ie5setup is a self-extracting executable that contains all
the files you will need.
Installing Internet Explorer 5
--------------------------------
NOTE: Internet Explorer should not be installed to the same directory
as an installation of a lesser version number. If you have installed
the beta version of Internet Explorer, it is recommended that you
remove this installation prior to upgrading.
1) Make the setup file executable; 'chmod +x ie5setup'.
2) Run the executable; './ie5setup'.
3) When Setup prompts for an installation directory, accept
the default directory or type in a new directory path.
(Note that installing to the default directory,
/usr/local/microsoft, may require root access.)
To run Internet Explorer 5:
After Internet Explorer 5 is installed, you can start the
browser by running "<installation directory>/bin/iexplorer".
Uninstalling Internet Explorer 5
----------------------------------
You must remove the current installation directory, for example,
'rm -r /usr/local/microsoft'.
Additionally, there is a directory named ".microsoft" in the home
directory for each user account that has run Internet Explorer at
least once. This directory may also be deleted if the user wishes to
remove all personal settings for Internet Explorer (including cookies,
history and favorites).
If you implemented CDE integration as explained below, you should
remove it by deleting the "IE5.dt" file from the system or user
directory.
=============================
CUSTOM PACKAGING VIA THE IEAK
=============================
The Internet Explorer Administration Kit (IEAK) allows administrators
to customize, configure, and restrict browser settings, lowering the
total cost of ownership to maintain a organization-wide installation
of Internet Explorer. The IEAK is available for this release; see
http://ieak.microsoft.com for registration and download information.
============
KNOWN ISSUES
============
Solaris Compatibility
---------------------
Use of any or all of these patches is subject to any license terms
that may accompany the patch.
o Solaris 2.4 and below
Internet Explorer is not supported on Solaris 2.4 and below.
o Solaris 2.5
To run Internet Explorer on Solaris 2.5 a patch is required. Patch
103093-17 or later corrects a multithreading issue.
NOTE: Additional patches from Sun Microsystems, Inc., may be
necessary to get full functionality from this patch. See the
patch's README for more details.
This patch is available from the "Public Patches" link on
http://sunsolve.sun.com/sunsolve/ or you can download the latest
version of this patch directly at:
ftp://sunsolve.sun.com/pub/patches/103093-25.tar.Z
Note that this patch number may become 103093-26 or higher in the
future as Sun Microsystems, Inc., upgrades it.
o Ultra 5's and 10's
To run Internet Explorer on an Ultra 5 or an Ultra 10, the following
Solaris Graphics patches are required:
For Sol 2.5.1 apply patch 103792-09 or later.
For Sol 2.6 apply patch 105362-10 or later.
o Miscellaneous
If the Sun's transparent shared memory is enabled, IE hangs on
startup. This is established to be a Sun Solaris Bug, reported as
bug 4144519.
Internet Explorer does not function on a Solaris 2.5.1 system with
early versions of the OpenWindows 3.5.1 XSun patch installed
(103566-xx). This patch is included as part of a recommended
cluster of patches offered by Sun Microsystems, Inc. A later version
of this patch, 103566-39, works correctly.
If you install Internet Explorer on a host machine, and use NFS to
mount the installation on another machine using a different
pathname, then you will not be able to execute Internet Explorer on
the second machine. Similarly, if you move the installation
directory to a different pathname, you will not be able to execute
Internet Explorer. In both cases you will receive the following
error message:
Support for SunOS <version> has not been installed on this system.
...where <version> indicates the currently running Solaris version.
To fix the problem, ensure that the environment variable MSFT_HOME
is set to the name of the installation directory before starting
Internet Explorer. For example, if you mounted or renamed the
installation directory as /net/myhost/local/ms, then execute this
command:
(csh) setenv MSFT_HOME /net/myhost/local/ms/
or
(sh) set MSFT_HOME=/net/myhost/local/ms/ ; export MSFT_HOME
You may use alternative approaches. For example, experienced users
may prefer to make a copy of the "bin/iexplorer" command, which is a
simple shell script, and change the directory reference on line 3.
If you have multiple platforms installed in a single directory, you
should set the environment variable MSFT_HOME to the name of the
installation directory before starting Internet Explorer or Outlook
Express.
Internet Explorer User Interface Issues
---------------------------------------
o IE does not display properly under GrayScale or GreyStatic mode.
o Address auto-complete does not always work as expected for addresses
with mixed case.
o In the Associations tab of the Internet Options Menu, the command line
field cannot contain output redirection statements
(e.g.: cat %1>/dev/audio).
o In the Programs tab of the Internet Options Menu, the script
specified cannot include command line arguments.
o Changes made to the user style sheet (Internet Options General tab,
Accessibility) take effect once Internet Explorer is restarted.
o Using Internet Explorer with the Exceed X Server may produce
undesirable interface side-effects. For example, the accelerator
keys or keyboard access to the address bar may not function.
o Experienced users of X11 can set color preferences using X resources
with the class name "Iexplorer". For detailed information about
these settings, see <installation directory>/ie/resources.txt.
Outlook Express Issues
----------------------
o Automatic disconnect
Some IMAP4 servers are configured to disconnect OE after a preset amount of
idle time. When this happens, OE will report the server disconnection with
a warning dialog. To reconnect, click on another mail folder which will
allow OE to automatically reconnect to the IMAP4 server.
o Upgrading from OE4 to OE5
OE will automatically upgrade your OE4 settings the first time OE5 is
run. Any changes made to your OE4 configuration after the upgrade will
not affect your OE5 configuration.
o Mail import from Unix files
OE will create duplicate copies of any messages that are imported
more than once. To prevent any confusion during mail import, it is best
to use an empty mail folder for import operations.
o Mail import from Netscape
OE is not able to automatically import unsent mail from Netscape.
o Upgrading from OE5 Beta
Upgrading from Beta versions of IE/OE is not supported. If the previous
version of OE is a beta version, be sure to install this version of OE
into an empty directory tree to prevent any potential conflicts with the
Beta pre-release software.
IEAK Issues
-----------
o Setup will not extract signed custom component CABs.
o A customized browser will not install to the same directory as a
previously customized browser installation.
o Windows carriage returns must be removed from custom mail, news, and
source viewer scripts added via the IEAK.
Type 'dos2unix <scriptname>' at the UNIX prompt.
o Setting the size of the Temporary Internet Files cache or
customizing toolbar buttons via an auto configuration script will
not take effect until restart.
o If you are running IIS4 (NTOP4) or have a custom http 404 error file
which exceeds 128 characters in length, some files needed for
branding may not be downloaded correctly upon auto configuration.
To work around this problem, extract the contents of config.cab to
the same location as the .INS file or reduce the length of the 404
error file returned by your web server.
Miscellaneous Issues
--------------------
o If an invalid name is given to the SOCKS proxy setting, Internet
Explorer will bypass the proxy altogether.
o News URLs which contain a # character in the message ID will fail to
open in the news viewer specified by the Internet Options Programs
tab.
o Internet Explorer may leave files in a temporary directory
(/var/tmp, /tmp, or the directory pointed to by the $TMPDIR
variable). These files are not needed and may be safely deleted
whenever Internet Explorer is not running.
o If you manipulate and/or delete files from the .microsoft directory
while the browser is running, the browser may hang.
o If different people share a common user ID, network authentications
made by one person may be available to others who are running
simultaneous copies of the browser.
o When downloading files, IE will sometimes append "(1)" to the first
extension in the filename, replacing the remainder of the filename
if it exists. For example xxx.tar.Z would be renamed xxx.tar(1).Z
o Download may fail if the Temporary Internet Files cache doesn't have
sufficient space to accommodate the downloaded file size. You can
change the amount of space allocated for Temporary Internet Files
size from the Internet Options General tab.
o When saving a file, IE may not append the correct file extension to
the filename suggested in the "Save As" dialog. For example, .Z
files may be saved as .z files, or the filename may have no
extension at all. Without this extension, IE will not reinterpret
the file correctly upon reopening. To work around this problem,
ensure the appropriate extension is appended to the filename before
saving.
o Internet Explorer 5 for UNIX supports most of the features and
technologies of Internet Explorer for Windows, but also differs in
some respects. For example, Internet Explorer for UNIX does not
support downloadable ActiveX controls or browsing and organizing
your local files and folders within the browser window. Other
unsupported features include filters/transitions in CSS, the DHTML
Editing component, and HTML Applications (HTAs). These differences
are noted in the comprehensive product documentation on MSDN Online
Workshop (http://www.msdn.microsoft.com/workshop).
o Internet Explorer for UNIX offers some features not found on the
Windows version as well, such as Emacs-style keyboard shortcuts and
external program associations. For a complete list of the latest
features in Internet Explorer 5 for UNIX, see the product home page
at http://www.microsoft.com/unix/ie.
==========
USER AGENT
==========
The User Agent String for Internet Explorer 5 is static except for the
third field which depends on the Operating System and the processor
you are using.
Here are some common configurations and the user agent strings
generated by Internet Explorer on these platforms:
Sparc 5, Solaris 2.5.1:
Mozilla/4.0 (compatible; MSIE 5.0; SunOS 5.5.1 sun4m; X11)
Any Ultra, Solaris 2.5.1:
Mozilla/4.0 (compatible; MSIE 5.0; SunOS 5.5.1 sun4u; X11)
Any Ultra, Solaris 2.6:
Mozilla/4.0 (compatible; MSIE 5.0; SunOS 5.6 sun4u; X11)
==========
USING JAVA
==========
Internet Explorer for Solaris integrates the Sun Microsystems Java
Virtual Machine (JVM) to support Java applets. The Sun JVM is natively
optimized for Solaris, includes a Just-in-Time (JIT) Compiler and
provides support for JDK 1.1.6. It is available for Solaris versions
2.5.1 and 2.6.
Note: Installation of the JVM is optional. If you do not install it,
a reminder will appear when Java content is encountered while
browsing. This reminder may be disabled when it appears, so that
applets will simply not display when encountered on Web pages.
In the event that you encounter issues while installing or using the
JRE or JDK, support and training are available at the web site
indicated below.
If you do not already have a version of Sun's JVM with support for JDK
1.1.6 or above installed on your system, have your system or network
administrator download and install the Java Run-time Environment (JRE)
for your platform from the following site:
http://www.sun.com/solaris/java
After the run-time is installed, simply add the bin directory
containing the "jre" executable to your UNIX path variable. Internet
Explorer will find and execute the first "java" or "jre" available in
this path. For example:
setenv PATH "$PATH:<JRE bin directory>"
Alternatively, you can set the MS_JAVA_VM environment variable to
point directly to your "jre" executable. For example:
setenv MS_JAVA_VM /bin/jre
This approach allows you to choose between multiple JVMs on your
system or to rename this particular JVM.
By default Internet Explorer does not display output from the JVM. To
enable output to the console, set the SHOW_MS_JAVA_OUTPUT variable to
true. For example:
setenv SHOW_MS_JAVA_OUTPUT true
Alternatively, if the "Java logging enabled" checkbox is selected in
the Internet Options Advanced tab, Internet Explorer will log JVM
output to ~/.microsoft/Java/javalog.txt.
You are now ready to have Java applets automatically launched in Sun's
Java Runtime Environment when encountered on web sites via Internet
Explorer.
Use of the JRE or JDK from Sun Microsystems is governed by the
licensing terms, conditions, and waivers that accompany it.
Java Packaging via the IEAK
---------------------------
The Runtime Environment for Java on Solaris can be included in your
Internet Explorer Administration Kit (IEAK) customized package.
Instructions to create the JRE package to redistribute via the IEAK
can be found by navigating to the following page:
http://www.microsoft.com/unix/ie/ie5/jvm.htm.
When the runtime is packaged according to these instructions, it will
be installed to <install>/external/sunos5/ when the user runs the
custom Internet Explorer setup program.
======================================
COMMON DESKTOP ENVIRONMENT INTEGRATION
======================================
If you run Internet Explorer within a CDE session, it will adopt the
CDE color scheme unless overridden with explicit color settings.
If you install Internet Explorer on Solaris 2.6, you will be asked
whether you wish to install Internet Explorer as the default browser
on your desktop. If you answer yes, the generic web browser icon will
launch Internet Explorer, and the default action for an HTML file will
be to launch Internet Explorer and open the file.
The setup program installs an IE.dt file on your system to enable this
CDE integration. If you are user "root", the file is added to the
directory /etc/dt/appconfig/types/C, and will affect all users on the
system. Otherwise, the file will be added to the directory
~/.dt/types, and will affect only you.
The file "IE.dt" is in the "ie" subdirectory of the installation, and
can be copied to other users' ~/.dt/types directory.
CDE integration can be removed by simply deleting the "IE.dt" file
from the system or user directories, and restarting the session.
There is a set of Internet Explorer icons for use with CDE, in the
ie/ie5icons subdirectory of the installation. They can be used by
administrators who want to place the Internet Explorer logo on the
desktop.
=========================================
AN ALTERNATIVE WAY TO ORGANIZE FAVORITES
=========================================
In addition to being able to organize favorites through the Internet
Explorer user interface, you can also manipulate your favorites
through the file system. Your favorites are organized and maintained
in the directory, ~/.microsoft/Favorites. You should shut down
Internet Explorer to make changes to this directory. The changes you
make will be reflected in your Favorites menu when you restart
Internet Explorer.
==========================
NTLM DOMAIN AUTHENTICATION
==========================
This release of Internet Explorer supports authenticating users
against Web servers which are configured to do NTLM Challenge Response
Authentication. NTLM Domain Authentication allows you to access your
organization's secure Windows-NT IIS/BackOffice based Intranet
applications from your UNIX desktop.
=======
SUPPORT
=======
Microsoft sponsors a public peer-to-peer newsgroup named
"microsoft.public.inetexplorer.unix". To access this newsgroup, use
Outlook Express to access the Microsoft public news server at
msnews.microsoft.com.
You may use Microsoft's online Knowledge Base to obtain detailed
product information at http://support.microsoft.com. The Knowledge
Base also contains late-breaking information and answers to frequently
asked customer questions, so check it often! To get information on
these products, specify Internet Explorer or Outlook Express in field
one and topic information in field two. Microsoft also offers
telephone-based technical support by calling Microsoft Technical
Support at (425)635-7123.
NOTE: We are always seeking individuals to participate in pre-release beta testing. If you'd like to receive future pre-releases of this product contact ieupriv@microsoft.com
Additional query words:
Keywords : kbtool msieunix
Version : UNIX:5
Platform : UNIX
Issue type : kbinfo