PC Ext: External Access Up to 50 NetWare Network Connections
ID: Q136489
|
The information in this article applies to:
-
Microsoft Mail for PC Networks, versions 3.2, 3.2a, 3.5
SUMMARY
The External Mail program, included with Mail for PC Networks, can access
up to 50 network connections by using the Novell NetWare VLM redirector.
NOTE: In earlier versions, External was limited to 8 network connections
with the older IPX - NETX redirector combination.
MORE INFORMATION
The following CONFIG.SYS, AUTOEXEC.BAT, and NET.CFG sample files provide an
example configuration for an External workstation:
CONFIG.SYS
DEVICE=c:\dos\himem.sys
device=c:\dos\emm386.exe noems
SHELL=c:\command.com /e /p:512
BUFFERS=30,0
FILES=50
LASTDRIVE=Z
AUTOEXEC.BAT
@echo off
PATH=c:\;c:\dosc:\nwclient
cd \nwclient
lh lsl
lh 3c509 (or other Multi-Link Interface Driver (MLID) network card)
lh ipxodi
lh vlm
login {mta login name} {password}
map f:=sys:maildata
map g:=server2\sys:maildata
map h:=server3\sys:maildata
.
.
. (additional drive mappings as needed)
.
.
.
external or a batch file that starts external
NET.CFG
show dots = on
file handles = 50
LINK SUPPORT
buffers 8 1586
Mempool 4096
Link Driver 3c509
port 300
int 10
Frame Ethernet_802.3
Protocol IPX 0 Ethernet_802.3
NetWare DOS Requestor
First Network Drive = F
Connections = 50
NOTE: The indentions in the NET.CFG file are required.
For more information about the NetWare VLM redirector, please refer to
"Inside NetWare 3.12" by Debra Niedermiller-Chaffins and Drew Hetwood
published by New Riders Publishing.
Additional query words:
3.20 3.20a 3.50
Keywords :
Version : WINDOWS:3.2,3.2a,3.5
Platform : WINDOWS
Issue type :