X400: Foreign System Ends Connection before Message Is Sent

ID: Q194685


The information in this article applies to:
  • Microsoft Mail Gateway to X.400, version 3.2


SYMPTOMS

When you attempt to send a message to a foreign system through the Microsoft Mail Gateway to X.400, the foreign system may end the connection before the message is completely transferred, and the X.400 log file may contain entries similar to the following:

  • 13:38:19 ERROR 3 (RTS): Sending message 0000120D failed


  • 13:38:19 ERROR 3 (RTS): Association aborted


  • 13:38:19 DEBUG (T4_recv): Connection 2: tp_receive() failed: 12


  • 13:38:19 ERROR 1 (MTSE): Error occurred in state 0



CAUSE

This problem occurs when the Microsoft Mail Gateway to X.400 sends invalid minor synchronization points to the foreign system.


RESOLUTION

A supported fix that corrects this problem is now available from Microsoft, but has not been fully regression-tested and should be applied only to systems experiencing this specific problem.

To resolve this problem, contact Microsoft Product Support Services to obtain the fix. For a complete list of Microsoft Product Support Services phone numbers and information on support costs, please go to the following address on the World Wide Web:

http://support.microsoft.com/support/supportnet/default.asp
The English version of this fix should have the following file attributes or later:

   File Name      Version
   ----------------------
   X400gate.exe   3.2.8 
This hotfix has been posted to the following Internet location as X400gy2k.exe:
ftp://ftp.microsoft.com/bussys/mail/pcmail-public/all-y2k/
NOTE: If you contact Microsoft to obtain this fix, a fee may be charged. This fee is refundable if it is determined that you only require the fix you requested. However, this fee is non-refundable if you request additional technical support, if your no-charge technical support period has expired, or if you are not eligible for standard no-charge technical support.

For more information about eligibility for no-charge technical support, see the following article in the Microsoft Knowledge Base:
Q154871 Determining If Your Product Is Eligible for No-Charge Technical Support


STATUS

Microsoft has confirmed this to be a problem in Microsoft Mail Gateway to X.400 version 3.2.

Additional query words:

Keywords : MailGWX400
Version : MS-DOS:3.2
Platform : MS-DOS
Issue type : kbbug


Last Reviewed: January 21, 2000