FP2000: FP98 Extended Server with Send to Database Form Handler Results in Error

ID: Q200973


The information in this article applies to:
  • Microsoft FrontPage 2000


SYMPTOMS

When you save a form using the Send to database form handler in FrontPage 2000 and then publish the Web to a FrontPage 98 extended server, the following error message may appear in Internet Explorer:

FrontPage Error.
User: Please report details to this site webmaster. Webmaster: Please see the server's application event log for more details.


CAUSE

Some programs are sent as arguments to the server extensions on the Web server during the HTTP publish operation. Versions of FrontPage earlier than version 2000 do not understand the arguments they are sent and thus cannot properly expand the arguments; they also cannot create the application root that allows the data connections to be read.


MORE INFORMATION

For information about using database functionality without server extensions, please refer to the following Microsoft Knowledge Base article:

Q233018 FP2000: Enabling Database Features Without the Server Extensions

Additional query words: fp2k

Keywords : kbdta
Version : WINDOWS:
Platform : WINDOWS
Issue type : kbprb


Last Reviewed: July 1, 1999
© 2000 Microsoft Corporation. All rights reserved. Terms of Use.