Cannot Print to Status Bar When Closing a Dialog Box
ID: Q123300
|
The information in this article applies to:
-
Microsoft Word for Windows, versions 6.0, 6.0a, 6.0c
SYMPTOMS
When you use the Print command in code in response to a button click that
closes a dialog box, the text in the status bar may flash by too quickly to
be seen.
CAUSE
Closing the dialog box resets the status bar.
STATUS
Microsoft has confirmed this to be a problem in Microsoft Word versions
6.0, 6.0a, and 6.0c for Windows. We are researching this problem and will
post new information here in the Microsoft Knowledge Base as it becomes
available.
MORE INFORMATION
The following sample macro demonstrates the behavior described in the
"Symptoms" section above.
WARNING: ANY USE BY YOU OF THE CODE PROVIDED IN THIS ARTICLE IS AT YOUR OWN
RISK. Microsoft provides this macro code "as is" without warranty of any
kind, either express or implied, including but not limited to the implied
warranties of merchantability and/or fitness for a particular purpose.
Sub MAIN
Begin Dialog UserDialog 109, 81, "Test", .DialogFunction
OKButton 10, 6, 88, 21
CancelButton 10, 30, 88, 21
PushButton 10, 54, 88, 21, "Text"
End Dialog
Dim dlg As UserDialog
x = Dialog(dlg)
End Sub
Function DialogFunction(identifier$, action, wvalue)
Select Case action
Case 1
Case 2
If identifier$ = "Text" Then
DialogFunction = 1
Print "Button pressed"
Else
Print "This is the text that will not be seen"
DialogFunction = 0
End If
Case 3
Case 4
Case 5
Case Else
End Select
End Function
Additional query words:
6.0 functions dynamic statement word6 winword
Keywords : kbmacroexample
Version : WINDOWS:6.0,6.0a,6.0c
Platform : WINDOWS
Issue type :