SUMMARY
In order for an HPGL graphic to print correctly from within Microsoft
Word for MS-DOS version 5.0 or 5.5, the graphic must be generated by
printing to a file in HP 7440A or ColorPro plotter format. Below is a
summary of the HPGL formatting instructions that are recognized from
within Microsoft Word.
HPGL Instruction Definition
---------------- ----------
CA set Designate alternate character set
CP spaces, line Character plot (decimal)
CS set Designate character set
DC send dots Digitize clear
DF Set default values
DI run,rise Set absolute label direction
(decimal)
DP Digitize Point
DR run,rise Set relative label direction
(decimal)
DT label terminator Define label terminator
(ASCII character)
EP Edge polygon
IM e(,s(,p)) Set e-,s-, and p-masks
IN Initialize plotter
IP P1x,P1y,(,P2x,P2y) Input P1 and P2 (integer)
IW X1, X2, Y1, Y2 Input window (integer)
LB c...c Label ASCII string
LT pattern number (,pattern length) Set line type (integer) and
pattern length (decimal)
NR Not ready (View state)
OC Output commanded position and
pen status
(integer return)
OD Output digitized point and pen
status (integer return)
OE Output error (integer return)
OF Output factors (integer return)
OH Output hard-clip limits
(integer return)
OI Output identification
(ASCII character return)
OO Output options (integer return)
OP Output P1 and P2 (integer return)
OS Output Status (integer return)
OW Output window (integer return)
PA X,Y,(,X,Y(,...)) Plot absolute to X,Y
(integer if not scaled or
decimal if scaled)
PD (X,Y(,...)) Pen down (integer)
PR (X,Y,(,X,Y(,...)) Plot relative from current pen
(integer if not scaled or
decimal if scaled)
PU (X,Y(,...)) Pen up (integer if not scaled or
decimal if scaled)
RA X,Y Fill rectangle absolute
(integer if not
scaled or decimal if
scaled)
RO n Rotate coordinate system (integer)
SA Select alternate character set
SC Xmin,Xmax,Ymin,Ymax User-unit scaling (integer)
SI width,height Set absolute character size
(decimal)
SL tan0 Set character slant from vertical
(decimal)
SM c Specify character for symbol
mode plotting (ASCII character)
SP pen number Select pen (integer)
SR width,height Select relative character size
(decimal)
SS Select standard character set
TL tp(,tn) Set tick length (decimal)
VS pen velocity Set velocity (decimal)
XT Draw X-axis tick
YT Draw Y-axis tick
Reference(s):
"Interfacing and Programming Manual for HP 7550A," Appendix C
Additional query words:
5.00 5.50
Keywords : kbgraphic kbprint
Version : MS-DOS:5.0,5.5,6.0
Platform : MS-DOS
Issue type :