The information in this article applies to:
SYMPTOMS
Advanced: Requires expert coding, interoperability, and multiuser skills.
RESOLUTIONWhen you use Access Basic to create a SQL pass-through query, set the ODBCTimeout property after you set the Connect property for the query. If you do not do this, the ODBCTimeout property is set to zero. STATUSMicrosoft has confirmed this to be a problem in Microsoft Access version 2.0. This problem no longer occurs in Microsoft Access version 7.0. MORE INFORMATIONThe ODBCTimeout property setting specifies the number of seconds Microsoft Access waits before a timeout error occurs on a query involving an ODBC database. When this property is set to zero, no timeout occurs. Steps to Reproduce ProblemNOTE: This example assumes that you have an ODBC data source (such as Microsoft SQL Server) available.
REFERENCESMicrosoft Access "User's Guide," version 2.0, Chapter 12, "Advanced Queries," pages 291-294 Additional query words: spt passthrough jet25 jet 2.5
Keywords : kbusage QryPass |
Last Reviewed: April 6, 1999 © 2000 Microsoft Corporation. All rights reserved. Terms of Use. |