ACC2: Use CurrentDB() Rather Than DBEngine(0)(0)
ID: Q131881
|
The information in this article applies to:
SYMPTOMS
Moderate: Requires basic macro, coding, and interoperability skills.
The "CurrentDB Function" topic in the Microsoft Access Help system makes
an incorrect recommendation in the "Note" section that reads as follows:
Note The CurrentDB function is included in this version of Microsoft
Access for compatibility with previous versions. It is recommended that
you use the Databases(0) element of the Databases collection instead.
For more information, see Examples of Converting Code to Version 2.0.
STATUS
This behavior no longer occurs in Microsoft Access version 7.0.
MORE INFORMATION
The correct recommendation is that you use the CurrentDB() function instead
of DBEngine(0)(0) for the following reasons:
- DBEngine(0)(0) is synonymous with the current database in Microsoft
Access version 2.0. However, this behavior is subject to change in
future versions.
- CurrentDB()and DBEngine(0)(0) have slightly different behaviors.
DBEngine(0)(0) returns a pointer to an object whereas CurrentDB()
creates a new object. This means that when you have two functions that
set database variables to DBEngine(0)(0), if the second function closes
DBEngine(0)(0), both functions are affected. When you return to the
first function, you may receive the following error message:
Object is no longer valid.
- DBEngine(0)(0) can sometimes reference the incorrect database. For
example, you can set a database object to the current database using
DBEngine(0)(0) in DB1.MDB, and then you can call a library database
that sets DBEngine(0)(0) to a global variable. If you close DB1.MDB,
open DB2.MDB, and reference DBEngine(0)(0).Name, you receive DB1.MDB
instead of DB2.MDB.
REFERENCES
For more information about the CurrentDB() function, search for
"CurrentDB," and then "CurrentDB Function (Data Access)" using the
Microsoft Access Help
menu.
Keywords : kbprg MdlDao