ACC: Form Is Inaccessible When Debugging Run-Time Error

ID: Q100133


The information in this article applies to:
  • Microsoft Access versions 1.0, 1.1, 2.0, 7.0, 97


SYMPTOMS

Moderate: Requires basic macro, coding, and interoperability skills.

If a form calls an Visual Basic for Applications function that is halted because of a run-time error, the form will become inaccessible.


CAUSE

When a program halts because of a run-time error, the form's handle is not released by the system. Even though the program is no longer running, the handle is still in use.


RESOLUTION

To release the form handle after the program has halted, click Reset on the module's Run menu.


MORE INFORMATION

Steps to Reproduce Behavior

  1. Create and save a form with the following command button on it:
    
          Object: Command Button
          ----------------------
          Caption: Run Code
          OnClick: =Test() 
    NOTE: In Microsoft Access version 1.x, the OnClick property is called the OnPush property.


  2. In a new module, create and save the following function named Test():
    
          Function Test()
          Dim x as Integer
             x = 1 / 0
          End Function 


  3. Open the form that you created in step 1.


  4. Click the Run Code button. Note that the program will halt and that you receive the error message "Division By Zero."


  5. Click Debug (or click OK in versions 1.x and 2.0).


  6. Minimize the module in which the function is being displayed.


  7. Try to click the Run Code button again, or try to move the form. Note that you cannot manipulate the form or anything on it. This is because the form handle is not available.


  8. To release the form handle after the program has halted, click Reset (or Reinitialize in version 1.x) on the module's Run menu.


Additional query words:

Keywords : kbprg PgmErr
Version : WINDOWS:1.0,1.1,2.0,7.0,97
Platform : WINDOWS
Issue type : kbprb


Last Reviewed: October 21, 1999
© 2000 Microsoft Corporation. All rights reserved. Terms of Use.