VB3 PRB: Can't Receive Data When Using MSCOMM.VBX Control

ID: Q124237


The information in this article applies to:
  • Microsoft Visual Basic Professional Edition for Windows, versions 2.0, 3.0


SYMPTOMS

While performing serial communications by using the MSCOMM.VBX control, you can get it to connect and send data, but not receive data.


CAUSE

You do not have the correct handshaking enabled.


RESOLUTION

To resolve this problem when using MSCOMM.VBX, set the RTSEnable property to True or add the following line of code to your program when you initialize the MSCOMM control:


   Comm1.RTSEnable = True 


MORE INFORMATION

The following information on the RTSEnable property comes from the Custom Control Help file (CTRLREF.HLP):

(RTSEnable) Determines whether to enable the Request To Send (RTS) line. Typically, the Request To Send signal that requests permission to transmit data is sent from a computer to its attached modem.

When RTSEnable is set to True, the Request To Send line is set to high (on) when the port is opened and low (off) when the port is closed. The Request To Send line is used in RTS/CTS hardware handshaking. The RTSEnable property allows you to manually poll the Request To Send line if you need to determine its state.

Additional query words: 2.00 3.00 comm communication custom

Keywords : PrgCtrlsCus
Version : 2.00 3.00
Platform : WINDOWS
Issue type :


Last Reviewed: June 24, 1999