FIX: Can't Set SelStart Property of RichTextBox to > 32K
ID: Q160233
|
The information in this article applies to:
-
Microsoft Visual Basic Standard, Professional, and Enterprise Editions, 32-bit only, for Windows, version 4.0
SYMPTOMS
You cannot set the SelStart property of RichTextBox controls that contain
text greater than 32K (32768) characters in length to a value greater than
32767 and less than the text length. Although this is a legal range,
SelStart is automatically set to the text length. Consequently, you cannot
make selections within this range.
STATUS
Microsoft has confirmed this to be a bug in the Microsoft products listed
at the beginning of this article. This bug has been fixed in Visual Basic
5.0.
RESOLUTION
Use the SendMessage API of USER32 with the EM_EXSETSEL parameter to set the
SelStart position:
Private Const WM_USER = &H400
Private Const EM_EXSETSEL = (WM_USER + 55)
Private Declare Function SendMessage Lib "USER32" Alias "SendMessageA"
(ByVal hwnd As Long, ByVal wMsg As Long, ByVal wParam As Long, lParam As
Long) As Long
Private Sub Command1_Click()
Dim x As String
x = String(32800, "a")
RichTextBox1.Text = x
'''[THE NORMAL WAY] RichTextBox1.SelStart = 32790
SendMessage RichTextBox1.hwnd, EM_EXSETSEL, 0, 32790
RichTextBox1.SelLength = 10
MsgBox RichTextBox1.SelText
End Sub
MORE INFORMATION
Steps to Reproduce Problem
- Start a new project in Visual Basic. Form1 is created by default.
- Place a RichTextBox, RichTextBox1, on Form1.
- Place a CommandButton, Command1, on Form1.
- Place the following code in the Click event of Command1:
Private Sub Command1_Click()
Dim x As String
x = String(32800, "a")
RichTextBox1.Text = x
RichTextBox1.SelStart = 32790
RichTextBox1.SelLength = 10
MsgBox RichTextBox1.SelText
End Sub
- Press the F5 key to run the project.
- Click Command1 and note that nothing is selected.