HOWTO: Use Windows 95 or Windows 98 as a DCOM Server
ID: Q165101
|
The information in this article applies to:
-
Microsoft Visual Basic Enterprise Edition for Windows, version 5.0
SUMMARY
To use a Windows 95 or Windows 98 computer as a Distributed Component
Object Model (DCOM) server, you need to configure the computer to run DCOM
applications. Using a Windows 95 or Windows 98 computer as a DCOM server
will not provide the same features as a Windows NT 4.0 computer.
Performance and security will be more limited. Additionally, you will have
to perform some steps manually that are provided automatically by Windows
NT. For instance, you will probably want to add shortcuts to the server
components in your startup group and you will need to run RPCSS.EXE before
you will be able to access the server component.
Because you need to have the server component running before trying to use
the client, you need some mechanism to keep the server running. The easiest
way to do this is to have a blank form in the server. You may set the
visible property of the form to "False."
MORE INFORMATION
DCOM was designed to run on Windows NT 4.0 Server and Workstation. DCOM is
also intrinsic Windows 98. To configure a Windows 95 computer for use as a
DCOM server, download DCOM95.EXE and DCM95CFG.EXE available from the OLE
Development section of the Microsoft Web Site at:
http://msdn.microsoft.com/library/default.htm
DCOM95.EXE is also available on the Microsoft Visual Basic 5.0 CD-ROM
(Enterprise, Professional and Standard editions) in the \Pro\Tools\DCOM95
directory.
After downloading and saving DCOM95.EXE, do the following:
NOTE: If you are setting up a Windows 98 DCOM Server, skip step 4.
- Double-click DCOM95.EXE and proceed through the installation of DCOM95.
This process requires you to reboot your system upon completion.
NOTE: If you intend to install DCM95CFG.EXE at the same time, you can
forgo rebooting your computer until the completion of DCM95CFG.EXE
installation.
- Double-click DCM95CFG.EXE. This will install the DCOMCNFG.EXE utility
that allows you to configure a DCOM server component. This requires you
to reboot your system upon completion.
- Change the key below in the Windows 95 registry:
HKEY_LOCAL_MACHINE\Software\Microsoft\OLE\EnableRemoteConnect
to the following:
Y
NOTE: Failure to set this key results in the following error on the
client:
"Run-time error '429': ActiveX component can't create object"
- Run DCOMCNFG on the Windows 95 or Windows 98 Server. Select the server
component and click the "Properties" button. Select the "Location" tab
and ensure that the "Run application on this computer" check box is
selected.
Select the "Security" tab. Select either "Use default access
Permissions" or "Use custom access permissions." If you opt to use
custom permissions, click the Edit button.
Use the "Add Access Permissions" dialog box to grant or deny access to
users of the server component. Click OK to close the "Add Access
Permissions" dialog box. Click OK again to close the "Access
Permissions" dialog box. Then click Apply to put your access permissions
into effect. If you do not set custom access permissions, your server
component will use the default access permissions for the computer.
Default access permissions are set from the "Distributed COM
Configuration Properties" dialog box. Select the tab labeled "Default
Security" to set access permissions as described above.
NOTE: Failure to set the access permissions will result in the
following error on the client:
"Run-time error '70': Permission denied"
- NOTE: This step is not required with DCOM95 version 1.1 or later.
While it is not necessary to place a shortcut to RPCSS.EXE (found in
your Windows\System folder) into your startup group, it is advisable
because RPCSS.EXE needs to be running on the server before clients can
connect.
NOTE: Failure to run RPCSS.EXE before attempting to connect to it will
result in the following error on the client:
"Run-time error '-2147023174 (800706ba)': Automation error"
This error message decodes to "The RPC server is unavailable."
- Place a shortcut to the server component you want to automate through
DCOM into the startup group. Again, this is not necessary, but because
the server component must be running before a client can access it,
this is a good technique to ensure the component is always running.
NOTE: Failure to run the server component results in the following
error on the client:
"Run-time error '429': ActiveX component can't create object"
REFERENCES
DCOM for Windows 95 release notes, located at:
http://www.microsoft.com/oledev
Additional query words:
rpcss kbAutomation kbDCOM kbVBp500 kbVBp kbDSupport kbdss
Keywords : kbGrpVB
Version : WINDOWS:5.0
Platform : WINDOWS
Issue type : kbhowto