FIX: Problems Retrieving Visual Basic 5.0 Projects from Visual SourceSafe

ID: Q171803


The information in this article applies to:
  • Microsoft Visual Basic Enterprise Edition for Windows
  • Microsoft Visual Studio, Enterprise Edition


SYMPTOMS

Retrieving a project from Visual SourceSafe into Visual Basic 5.0 may result in one of the following errors:

"Failed to reload project .... "
-or-
"Application error"
-or-
"The instruction at '0x0fa659de' referenced memory at '0x30303030'. The memory could not be read."


STATUS

Microsoft has confirmed this to be a bug in the Microsoft products listed at the beginning of this article. This bug has been fixed in Visual Studio 97 Service Pack 2.

For more information on the Visual Studio 97 Service Pack 2, please see the following article in the Microsoft Knowledge Base:

Q170365 : INFO: Visual Studio 97 Service Packs - What, Where, and Why
For a list of the Visual Basic 5.0 bugs that were fixed in the Visual Studio 97 Service Pack 2, please see the following article in the Microsoft Knowledge Base:
Q171554 : INFO: Visual Basic 5.0 Fixes in Visual Studio 97 Service Pack 2

Additional query words: kbDSupport

Keywords : kbVBp500 kbVS97sp2fix kbGrpVBDB kbvbp500sp2fix
Version : WINDOWS:
Platform : WINDOWS
Issue type : kbbug


Last Reviewed: January 5, 2000