PRB: User Connection Object Connect Property Remains Populated
ID: Q177592
|
The information in this article applies to:
-
Microsoft Visual Basic Enterprise Edition for Windows, versions 5.0, 6.0
SYMPTOMS
When a UserConnection object is declared at the global level, the userid
and password stored in the Connect property remains populated after the
connection is closed.
RESOLUTION
To make sure the userid and password in Connect property is cleared after
closing the connection, you can set the user connection object to Nothing
right after closing the connection, such as:
uc.close
SET uc = Nothing
You could also store the initial value of the Connect property to a
variable, and replace the Connect property with that value after the
connection is closed, such as the following:
Dim myConnect As String
myConnect = uc.Connect
uc.EstablishConnection
uc.Close
uc.Connect = myConnect
STATUS
Microsoft is researching this problem and will post new information here in
the Microsoft Knowledge Base as it becomes available.
MORE INFORMATIONSteps to Reproduce Behavior
Task 1: Create the UserConnection
- Start a new project in Visual Basic and choose "Standard EXE." Form1
is created by default.
- From the Project menu, select Components, select the Designers tab, and
then place a check next to Microsoft UserConnection.
- From the Project menu, select Add ActiveX Designer, and then select
Microsoft UserConnection. This will bring up a dialog titled
"UserConnection1 Properties."
- On the Connection tab, select either a DSN or DSN-less connection and
fill in the appropriate information. On the Authentication tab, leave
User Name and Password blank. At ODBC Prompt Behavior dropdown box,
choose "Only when needed."
- Click OK to save this information and return to the Designer window.
Task 21: Build the Visual Basic Code
- Add two CommandButtons, Command1 and Command2, to Form1. Command1
establishes the connection; Command2 closes it Both display the Connect
property in the debug window.
- Paste the following code in the General Declaration section of Form1:
' *** To workaround the problem:
' *** Uncomment the 2 lines of VB code to re-set
' *** Connect property using variable myConnect
' ***
Dim uc As New UserConnection1
Dim myConnect As String
Private Sub Command1_Click()
' myConnect = uc.Connect
Debug.Print uc.Connect
uc.EstablishConnection
End Sub
Private Sub Command2_Click()
uc.Close
' uc.Connect = myConnect
Debug.Print uc.Connect
End Sub
Private Sub Form_Load()
Command1.Caption = "Establish Connection"
Command2.Caption = "Close Connection"
End Sub
Private Sub Form_Unload(Cancel As Integer)
Set uc = Nothing
End Sub
- Press F5 key to start the program.
NOTE: Because the userid and password remain populated in the Connect
property after closing the connection, you are only prompted once for the
authentication information after the first connection is established.
REFERENCES
For additional information about User Connection Designer, please see the
following article in the Microsoft Knowledge Base:
Q166281 HOWTO: Create and Implement a UserConnection
(c) Microsoft Corporation 1997, All Rights Reserved.
Contributions by Adrian Chiang, Microsoft Corporation
Additional query words:
kbVBp500 kbVBp600 kbdse kbDSupport kbVBp
Keywords : kbGrpVBDB
Version :
Platform : WINDOWS
Issue type : kbprb
|