FIX: Heap Walker ASCII Display Drops Characters

ID: Q180844


The information in this article applies to:
  • Microsoft Windows CE Toolkit for Visual Basic 5.0, version 1.0


SYMPTOMS

When using the Memory Dump window in the Heap Walker, the ASCII column may not show a complete line of 16 ASCII symbols.


CAUSE

The program incorrectly determines the number of characters to display.


RESOLUTION

Each line in the Memory Dump window in the Heap Walker displays 16 hexadecimal values. Although the corresponding ASCII symbols are not all displayed, it is possible to convert the hexadecimal numbers to their ASCII equivalents manually.


STATUS

Microsoft has confirmed this to be a problem in the Microsoft products listed at the beginning of this article.

This problem was corrected in Windows CE Toolkit for Visual Basic 6.0.

Additional query words: vbce vbce5 vbce6

Keywords : kbToolkit kbVBp kbVBp500bug kbVBp600fix kbWinCE kbWinCE100 kbGrpVB
Version : WINDOWS:1.0
Platform : WINDOWS
Issue type : kbbug


Last Reviewed: February 25, 1999