The information in this article applies to:
SYMPTOMSWhen building a project from the command line using the following custom macros, you will encounter undetermined errors. MSDevDirNOTE: For information about these custom macros, please see "Using Argument Macros" in the Visual C++ Users Guide. CAUSE
These custom macros are not assigned in the .mak file. For example,
$(MSDevDir)\binexpands to this: \bin RESOLUTIONDefine these macros in the NMAKE command line to work around this problem. For example, NMAKE /f MyProject.mak MsDevDir=C:\MSDEV<Enter>Note that the macros are case-sensitive. STATUSMicrosoft has confirmed this to be a bug in the Microsoft products listed at the beginning of this article. Additional query words: kbVC400bug MSDEV
Keywords : kbVC400bug kbVC410bug kbVC420bug kbVC500bug kbVC600bug NmakeIss |
Last Reviewed: May 15, 1999 © 2000 Microsoft Corporation. All rights reserved. Terms of Use. |