FIX: Sample Application Dialog Box Is Disabled in InfoViewer

ID: Q140088


The information in this article applies to:
  • The Development Environment, included with:
    • Microsoft Visual C++, 32-bit Editions, version 4.0
    • Microsoft FORTRAN PowerStation 32 for Windows NT, version 4.0


SYMPTOMS

In the InfoViewer, when looking at the sample documentation, the button labeled "Click to open or copy the XXX project files" may be disabled. This button normally brings up the Sample Application dialog box to get the sample code.

In some samples, the button is labeled STEP1, STEP2, STEP3, and so on.


CAUSE

If you press ALT+F4 or an equivalent key combination to close the dialog box the first time it comes up, it doesn't close correctly. Even though the dialog box is no longer visible, it isn't actually dismissed and can still be seen in Spy++. It will have a title similar to this one:


   Window 004601D0 "Sample Application" #32770 (Dialog) 
Because the dialog box isn't actually gone, clicking the button can't restore it.


RESOLUTION

To work around the problem and gain access to the sample files, press the ESC key and try again, or exit and then restart the Developer Studio.


STATUS

Microsoft has confirmed this to be a bug in the Microsoft products listed at the beginning of this article. This bug was corrected in Visual C++ 4.1.


MORE INFORMATION

Steps to Reproduce Problem

  1. From the InfoView in the Workspace window, open one of the samples such as:

    CUSTOMWZ: A Custom AppWizard


  2. Click the button labeled "Click to open or copy the CUSTOMWZ project files." This will bring up the Sample Application dialog box, which will allow you to select and open any of the files for the sample.


  3. Dismiss the Sample Application dialog box by pressing ALT+F4, by double-clicking the control-menu box in the upper-left corner, or by clicking the X in the upper-right corner of the window in Windows 95.


  4. Click the button labeled "Click to open or copy the CUSTOMWZ project files" again. This will do nothing.


  5. Start Spy++, and look for the Sample Application dialog window. It will be there even though it should not (because it was 'closed').


  6. Back in InfoView, select a different sample. Bring up the Sample Application dialog box, and close it by pressing the ESC key or by clicking the Close button on the dialog box. This time the Sample Application dialog box will close properly, so it can be re-opened.


Additional query words: kbVC400bug kbvc410fix utilities kbnoupdate

Keywords : kbide kbVC kbVC410fix
Version : 4.00
Platform : NT WINDOWS
Issue type : kbbug


Last Reviewed: July 27, 1999
© 2000 Microsoft Corporation. All rights reserved. Terms of Use.