The information in this article applies to:
SYMPTOMSWhen you build an .ocx, Regsvr32.exe is always called whether or not the compilation succeeds. If you start the build by pressing F5 (Build:Debug :Go), and there are compiler errors, after Regsvr32.exe is run, the debugger will be launched if you have an existing copy of your debug executable. This same problem occurs on any project that uses a custom build option for the project. Note that having custom build settings for individual files in the project will not effect this behavior. RESOLUTIONRemove the custom build command, and add a custom tool to the Tools menu. In the case of the .ocx file, Regsvr32 is already registered as a Tool. You can run Regsvr32 as a separate step when necessary. STATUSMicrosoft has confirmed this to be a bug in the Microsoft products listed at the beginning of this article. This bug was corrected in Visual C++ version 5.0. MORE INFORMATIONSteps to Reproduce Problem