PRB: Visual C++ 4.0 or 4.1 Setup Fails to Copy Shared DLLs
ID: Q148882
|
The information in this article applies to:
-
The Microsoft Visual C++ Setup
-
Microsoft Visual C++, 32-bit Editions, versions 4.0, 4.1
SYMPTOMS
When you install Visual C++ 4.x in either Windows 95 or Windows NT, it is
possible for setup to fail while copying certain shared DLLs. The DLLs that
don't copy successfully will most likely be one of these:
MSVCRT20.DLL MSVCRT40.DLL
ODBCCP32.DLL ODBC32.DLL ODBCINT.DLL
When setup fails, it displays a dialog box that looks similar to this:
Setup cannot open the destination file
'C:\Windows\System\Msvcrt20.dll'. The file may be in use by
another application, or marked read-only. Close the application
or change the file's read-only attribute and try again.
-or-
Cannot install file C:\Windows\System\Odbc32.dll. It might be
in use. Try closing all applications and choosing Retry.
Both dialog boxes offer a chance to Abort, Retry, or Ignore.
CAUSE
Many applications use shared DLLs. If the setup program tries to copy a DLL
over another DLL that has the same name while that DLL is in use by another
program, the setup program will fail.
For example, the Windows 95 Explorer uses Msvcrt20.dll, so if the Explorer
is not closed before running Visual C++ 4.x setup, you could see the
problem. You may also see the problem when running The Internet Information
Server as it also uses some of these DLLs.
RESOLUTION
Here are several possible resolutions:
- The best resolution is to make sure no other applications are running
when you install Visual C++ 4.x. To do this, close all applications, and
check the task list to make sure nothing is running. Under Windows 95,
you can make sure other processes are not running by restarting your
computer; hold down the SHIFT key as Windows 95 restarts to bypass the
startup group.
- An additional workaround is to start Visual C++ Setup in the following
manner:
- Under Windows 95:
Close all applications including Explorer. Run setup from an MS-DOS
window. If you are installing from the network, map to that drive.
- Under Windows NT 3.51:
Close all applications. Run setup from File Manager or a DOS window.
- If all applications are closed, but the error still occurs, make sure
that you close the Master Setup window; it uses Msvcrt20.dll.
- If the problem persists, it is generally safe to click Ignore, and
continue with the installation. However, remember to manually copy the
files from the Visual C++ CD-ROM that failed to copy during the setup.
- Another slightly riskier way to work around the problem is to rename
the offending DLL from the system directory. Once the installation
completes, restart your computer to cause the new version to be loaded.
STATUS
This behavior is by design.
Additional query words:
Keywords : kbenv kbsetup vc40setup
Version : 4.0 4.1
Platform : NT WINDOWS
Issue type : kbprb
|