PRB: VB Does Not Support Dual Interfaces in OLE Controls
ID: Q151903
|
The information in this article applies to:
-
The Microsoft Foundation Classes (MFC), included with:
-
Microsoft Visual C++, 32-bit Editions, versions 4.0, 4.1
-
Microsoft Visual Basic Learning, Professional, and Enterprise Editions for Windows, version 4.0
-
Microsoft Visual Basic Standard, Professional, and Enterprise Editions, 32-bit only, for Windows, version 4.0
SYMPTOMS
ActiveX Controls that implement a Dual Interface do not use early binding
when placed on a Visual Basic form. Even if the Dual Interface is marked as
the default interface in the ActiveX Control's .odl file, Visual Basic
still uses the standard IDispatch interface for all automation calls.
STATUS
This behavior is by design.
MORE INFORMATION
Dual Interface provides an alternative to using the standard IDispatch
interface when making Automation calls. This technique is also referred
to as Early Binding because type checking is performed at compile time.
Dual Interfaces are rapidly becoming popular because they provide increased
performance over the standard IDispatch interface.
It is possible to add Dual Interface support to automation servers as well
as ActiveX Controls. The ACDUAL sample provided with Visual C++ 4.1
demonstrates the addition of a Dual Interface to the AutoClick automation
server. Tech Note 65, referenced in the References section below, outlines
the changes you must make to an automation server to support a Dual
Interface. Although ACDUAL and Tech Note 65 refer to automation servers,
the information they provide is also applicable to ActiveX Controls.
Visual Basic does support early binding for automation servers that support
a Dual Interface, but currently does not support Dual Interface ActiveX
Controls. If you attempt to use the Dual Interface on an ActiveX Control in
Visual Basic, the standard IDispatch interface is used instead. Future
versions of Visual Basic may take advantage of Dual Interface ActiveX
Controls, but Visual Basic 4.0 does not.
REFERENCES
ACDUAL Sample - MFC OLE Samples, Visual C++ 4.1
Tech Note 65: Dual-Interface Support for OLE Automation Servers
Additional query words:
Keywords : kbole kbCtrl kbMFC kbVC
Version : winnt:4.0 4.1;win95:4.0,4.1
Platform : Win95 winnt
Issue type : kbprb