PRB: New Project Wizard Generates Error (-2147220496)

ID: Q195352


The information in this article applies to:
  • Microsoft Visual InterDev, version 6.0


SYMPTOMS

When creating a new Web project with the Visual InterDev New Web Project Wizard, the following error occurs:

A reserved error occurred (-2147220496)
The error occurs after you have named the project and clicked Next.


CAUSE

Two components, Comctl32.ocx and Comdlg32.ocx, have been overwritten by older components installed with Visual InterDev 6.0.


RESOLUTION

Replace the older versions of these files with the newer versions:

  • Comctl32.ocx version 6.00.8022 or greater


  • Comdlg32.ocx version 6.00.8169 or greater


You can find these components on disk 1 in the OS\System directory of the Visual Studio 98 CD or the Visual InterDev 6.0 Professional version CD. Replace the older versions with the newer versions from the CD. Register the components using REGSVR32, reboot your machine, and create a new Web project.


MORE INFORMATION

The error "A reserved error occurred (-2147220496)" also has other distinct causes. For additional information, please see the following articles in the Microsoft Knowledge Base:

Q167846 FIX: Reserved Error When Running DataForm Wizard Against
Q166674 BUG: Reserved Error when Entering Certain Valid SQL Statements

Keywords : kbide kbVisID600 kbGrpASP
Version : WINDOWS:6.0
Platform : WINDOWS
Issue type : kbprb


Last Reviewed: October 29, 1999