PRB: How to Handle the "invalid serial number" Error
ID: Q123469
|
The information in this article applies to:
-
Microsoft SourceSafe for MS-DOS, versions 2.0x, 3.01, 3.02
-
Microsoft SourceSafe for Windows, versions 2.0x, 3.01, 3.02
-
Microsoft SourceSafe for Macintosh, versions 2.0x, 3.01, 3.02
-
Microsoft SourceSafe for Windows NT, versions 2.0x, 3.01, 3.02
-
Microsoft SourceSafe for UNIX, versions 2.0x, 3.01, 3.02
SYMPTOMS
The error "invalid serial number" occurs when a DEMO serial number has
expired.
RESOLUTION
Issue a updated serial number by following these steps:
- Run SERIALIZ on the computer with outdated serial number. For example:
C:\SS\ADMIN\SERIALIZ <data directory>
This command gives a list of current serial numbers.
- Install a new serial number. For example:
C:\SS\ADMIN\SERIALIZ <data directory> -s<serial_num>
You can also reinstall the demo diskette to restart the 30 day period.
Additional query words:
Keywords : kberrmsg kbusage SourceSafe vbwin ss3
Version : 3.01 3.02
Platform : MACINTOSH MS-DOS NT UNIX WINDOWS
Issue type :
|