PRB: VSS OLE Add-in Model Not Supported by Visual Basic 4.0

ID: Q157715


The information in this article applies to:
  • Microsoft Visual SourceSafe, 32-bit, for Windows 5.0
  • Microsoft Visual Basic Enterprise Edition for Windows, version 4.0


SYMPTOMS

When creating an add-in OLE server with Visual Basic 4.0, Visual SourceSafe may crash or may not register the add-in properly.


CAUSE

Visual Basic 4.0 does not support creating OLE interfaces. This is required by the OLE automation add-in model in order to create an add-in OLE server.


RESOLUTION

A language that supports OLE interfaces, such as Microsoft Visual C++, should be used.


STATUS

This behavior is by design.


MORE INFORMATION

The Visual SourceSafe add-in model expects an IVSSEventHandler interface that has an INIT event exposed. If this interface is not available, Visual SourceSafe cannot establish the communication channel between itself and the add-in OLE server.

Additional query words:

Keywords : kbinterop kbSSafe500 kbVBp400
Version :
Platform :
Issue type : kbprb


Last Reviewed: August 13, 1999