MOD2000: Undoing Checkout in Visual SourceSafe Deletes New Tables and Data Access Pages

ID: Q236479


The information in this article applies to:
  • Microsoft Office 2000 Developer
  • Microsoft Access 2000

Moderate: Requires basic macro, coding, and interoperability skills.

This article applies only to a Microsoft Access database (.mdb).


SYMPTOMS

When you undo the checkout of Data and Misc. Objects for a Microsoft Access database under Microsoft Visual SourceSafe control, you lose any tables or links to a data access page that you created after you checked out the object.


CAUSE

Visual SourceSafe stores all of the tables and links to pages in Data and Misc. Objects as a single object. Therefore, if you undo the checkout of that object, Visual SourceSafe reverts to the stored version.


RESOLUTION

The stored version of Data and Misc. Objects does not contain any information about the new table. After you undo the checkout, there's no way to recover the new table.

However, the HTML file for the data access page is not part of Data and Misc. Objects. Therefore, the HTML file of the new page remains in the folder where it was saved. You can create a new link to the HTML file. To do so, follow these steps:

  1. Remove the database from Visual SourceSafe control.


  2. Open the database.


  3. In the Database window, click Pages under Objects, and then click New.


  4. In the New Data Access Page dialog box, click Existing Web Page, and then click OK.


  5. Locate the existing HTML file and click Open.


  6. On the File menu, click Save.


  7. Add the database back to Visual SourceSafe control.


For more information about removing a database from Visual SourceSafe control, click Contents on the Help menu, click the Index tab in Visual SourceSafe Help, type the following text:
files
and then double-click the selected text to go to the "files, delete and recover" topic.


MORE INFORMATION

Steps to Reproduce Behavior

  1. Open the sample database Northwind.mdb.


  2. On the Tools menu, point to SourceSafe, and then click Add Database to SourceSafe. Click Yes when prompted to close the database.


  3. If you see the Visual SourceSafe Login dialog box, type a valid user name and password, and then click OK.


  4. In the Add to SourceSafe Project dialog box, type Northwind in the Project box, and then click OK. Click Yes when prompted to create the project.


  5. In the Add Objects to SourceSafe dialog box, click Select All, and the click OK.


  6. On the Tools menu, point to SourceSafe, and then click Check Out.


  7. In the Object Type list, click Other. Click to select the Data and Misc. Objects check box, and then click OK.


  8. Create and save a new table as tblVSSTest.


  9. Close the table. Note that you see the tblVSSTest table in the Database window.


  10. On the Tools menu, point to SourceSafe, and then click Undo Check Out.


  11. In the Object Type list, click Other. Click to select the Data and Misc. Objects check box, and then click OK.


  12. When you see the following warning, click Yes:


  13. The Data and Misc. Objects may have changed. Undo checkout and lose changes?
    Note that the new tblVSSTest table no longer exist.

Additional query words: prb vss miscellaneous

Keywords : kbdta AccCon
Version : :; WINDOWS:2000
Platform : WINDOWS
Issue type : kbprb


Last Reviewed: September 10, 1999
© 2000 Microsoft Corporation. All rights reserved. Terms of Use.