Unable to Run Windows Sockets Utilities with TCP/IP-32

ID: Q122448


The information in this article applies to:
  • Microsoft TCP/IP-32 for Windows for Workgroups, version 3.11
  • Microsoft Windows for Workgroups


SYMPTOMS

When you run any Windows Sockets utilities, such as IPCONFIG, on a Windows for Workgroups version 3.11 computer configured with Microsoft TCP/IP-32, either of the following error messages may appear:

Unable to initialize winsock
Failed to retrieve required information from TCP/IP


RESOLUTION

To correct this problem, use a text editor such as Notepad to open and edit the SYSTEM.INI file. In the [386enh] section, verify the following line and add any parameters if missing:

netmisc=ndis.386, ndis2sup.386, wsock.386, wstcp.386
NOTE: Make sure these files reside in the \WINDOWS\SYSTEM sub-directory.

Additional query words: wfw wfwg prodtcp32 3.11

Keywords : NTInterop nttcp
Version : WINDOWS:
Platform : WINDOWS
Issue type :


Last Reviewed: October 1, 1999