The information in this article applies to:
SYMPTOMSTyping MODE COMx:19200 results in the following error message:
CAUSE
IBM PS/2-style computers support extended INT 14h services that allow
the baud rate to be set up to 19200. MODE uses this extended function
support to initialize COM ports on PS/2-style systems.
WORKAROUND
Rather than using MODE to set the baud rate, use an application that
controls the COM port to set the baud rate.
MORE INFORMATIONThis information is true for previous versions of MODE.COM as well the version in Windows 95. Additional query words: 3rdparty
Keywords : |