The information in this article applies to:
SYMPTOMSWhen you try to run the IBM DIAGS.COM utility in a windowed MS-DOS prompt session, the utility does not run and you receive the following error message: If you click the Details button you receive the following information:
CAUSEThis error occurs because the DIAGS.COM utility tries to access the Token Ring adapter directly. This adapter is protected by the Windows 95 protected-mode network adapter driver. RESOLUTIONTo work around this problem, run the DIAGS.COM utility in MS-DOS mode. To do so, follow these steps:
MORE INFORMATION
The DIAGS.COM utility is used to test IBM 16/4 Token Ring adapters.
Additional query words: tr token-ring token/ring 16-4
Keywords : |