Re-enabling CMD PCI IDE Controller Hangs Computer

ID: Q136106


The information in this article applies to:
  • Microsoft Windows 95


SYMPTOMS

If you re-enable a disabled CMD PCI controller in Device Manager and click OK when you are prompted "Do you want to restart your computer now," the computer beeps repeatedly and stops responding (hangs). Or, the computer may restart normally but the CMD PCI controller may remain disabled in Device Manager.


CAUSE

Windows 95 does not support dynamic disabling and re-enabling of PCI IDE controllers.


RESOLUTION

To re-enable the CMD PCI controller, use either of the following methods:

Method 1

Reinstall Windows 95. To do so, run Setup from the command prompt.

Method 2

  1. Restart your computer in Safe Mode. To do so, restart your computer, press the F8 key when you see the "Starting Windows 95" message, and then choose Safe Mode from the Startup menu.


  2. In Control Panel, double-click System.


  3. On the Device Manager tab, double-click the Hard Disk Controllers branch to expand it.


  4. Click the CMD PCI IDE controller, and then click Remove.


  5. Once the device is removed, restart Windows 95 normally. The CMD PCI controller should be redetected automatically. After Windows 95 installs the drivers for the controller, restart the computer.


Additional query words: cmd640 cmd640x

Keywords : win95
Version : 95
Platform : WINDOWS
Issue type :


Last Reviewed: June 4, 1999
© 2000 Microsoft Corporation. All rights reserved. Terms of Use.