Cannot Monitor Recording with Compaq ESS ES688 Sound Chip
ID: Q139017
|
The information in this article applies to:
SYMPTOMS
When you try to record a .wav file from an audio CD using the Compaq ESS
ES688 integrated sound chip, the sound from the CD may stop playing while
the recording is in progress. The sound does not return until you stop
recording.
CAUSE
This behavior can occur if the Monitor While Recording option is not
turned on in the Mixer tool. By default, this option is turned off with
the Compaq ESS ES688 AudioDrive.
RESOLUTION
Turn on the Monitor While Recording option in the Mixer tool. To do so,
follow these steps:
- Use any text editor (such as Notepad) to open the System.ini file.
Verify that the line "drivers=msmixmgr.dll" exists in the [boot]
section of the file. If the line does not exist, add it, save the
file, and then restart your computer.
- Start the Mixer tool by double-clicking the speaker icon on the
taskbar.
- On the Options menu, click Properties.
- Click the Recording option, and verify that there is a check mark
in the Recording Controls check box. If there is no check mark,
click the Recording Controls check box to select it. Click OK.
- On the Options menu, click Advanced Controls to display the advanced
controls.
- Click the Advanced button.
- In the Other Controls section, click the Monitor While Recording
check box to select it. Click OK.
Keywords : win95
Version : 95
Platform : WINDOWS
Issue type :