The information in this article applies to:
SYMPTOMSIf a file on a Novell NetWare network server is opened by a Windows 95 client running the Microsoft Client for NetWare Networks (NWRedir), and the size of the file subsequently changes, the new file size may not be reported by Windows 95. CAUSEIf a file is being cached, the GetFileSize API returns cached file size information, instead of reading the actual file size from the server. RESOLUTIONThis issue is resolved by the following updated file for Windows 95 and OSR2, and later versions of this file:
STATUS
Microsoft has confirmed this to be a problem in Microsoft Windows 95 and
OEM Service Release 2 (OSR2). An update to address this problem is now
available, but is not fully regression tested and should be applied only
to computers experiencing this specific problem. Unless you are severely
impacted by this specific problem, Microsoft does not recommend
implementing this update at this time. Contact Microsoft Technical Support
for additional information about the availability of this update.
MORE INFORMATION
In a situation where multiple clients access and make changes to a single
network file without locking the file to enforce data integrity, NWRedir
may not reflect the current file data due to its implementation of
caching. In the absence of locking, some programs may check for changes
in the file size using the GetFileSize API.
Q177222 NetWare Printers or Volumes Unavailable in Windows 95 For additional information about Windows 95 updates, please see the following article in the Microsoft Knowledge Base: Q161020 Implementing Windows 95 Updates
Keywords : win95 |
Last Reviewed: June 30, 1999 © 2000 Microsoft Corporation. All rights reserved. Terms of Use. |