SYSTEM.INI Setting Required for AST VGA Plus

ID: Q58303


The information in this article applies to:
  • Microsoft Windows versions 3.0, 3.0a, 3.1, 3.11

For proper operation in Microsoft Windows 386 enhanced mode on the AST VGA Plus card, the following line is required in the [386Enh] section of the SYSTEM.INI file:

   EMMEXCLUDE=C000-C500 
This requirement is due to nonstandard ROM mapping by the AST VGA Plus.

If this line is not included, the system may stop responding (hang or lock up) when starting or running Windows in 386 enhanced mode.

Additional query words: 3.00 3.0 3.0a 3.00a hang lock freeze win30 KBHW 3.10 3.11 win31

Keywords :
Version : WINDOWS:3.0,3.0a,3.1,3.11
Platform : WINDOWS
Issue type :


Last Reviewed: December 8, 1999
© 2000 Microsoft Corporation. All rights reserved. Terms of Use.