Toshiba T1200XE Needs /M: toshiba for Standard-Mode Windows
ID: Q64263
|
The information in this article applies to:
-
Microsoft Windows versions 3.0, 3.0a
SUMMARY
The Toshiba T1200XE cannot run standard-mode Microsoft Windows version
3.0 without the HIMEM.SYS parameter /M:toshiba. This line is inserted
if the Setup program's choice of "MS-DOS or PC-DOS System" is overridden
and Toshiba T1600 is chosen instead. This is not the case for the Toshiba
T1200 (plain), which runs Windows correctly if it is set up for "MS-DOS or
PC-DOS System."
NOTE: Running the maintenance Setup from the Windows directory or from the
Windows Setup icon does not add the /M:toshiba line to the CONFIG.SYS. You
must go back through Setup or add this parameter manually.
MORE INFORMATION
The Toshiba T1200XE was released shortly before Windows 3.0. As a result,
it was not possible to test on this machine and include the Toshiba on the
Hardware Compatibility List.
It has been reported that if this machine is set up for CGA, the screen
that shows the hardware detected by Setup doesn't show any detected display
and the last line, which should be highlighted, is not. If you use the
arrow keys to move from line to line, the selected line can't be seen. You
can work around this by running SETUP /I to disable auto-detection of the
hardware and choosing COMPAQ PORTABLE PLASMA display and Toshiba 1600 as
mentioned above. This allows the Setup program to run correctly, and
Windows 3.0 works properly after Setup.
Microsoft is researching this problem and will post new information here as
it becomes available.
Additional query words:
3.00 3.00a 3.0 3.0a KBHW
Keywords :
Version : WINDOWS:3.0,3.0a
Platform : WINDOWS
Issue type :