SYMPTOMSWhen using Quantum's Plus Hardcard XL and Windows, you receive the following Windows error message:
CAUSEThis error occurs if you are using the earlier ATDOSXL.SYS device driver, version 1.50. WORKAROUNDTo work around this problem, add the /W switch to the device driver in the CONFIG.SYS file. The new line should read as follows: DEVICE=ATDOSXL.SYS /W MORE INFORMATION
Quantum has released a Windows-compatible device driver (version 1.70) for
the Plus Hardcard XL that does not require the /W switch. The new driver
can be obtained from Quantum's bulletin board service (BBS) by calling
(408) 894-3214.
The products included here are manufactured by Quantum, a vendor independent of Microsoft; we make no warranty, implied or otherwise, regarding these products' performance or reliability. Additional query words: 3.00 3.00a 3.10 win30 win31 3rdparty plus 3.11 development