The information in this article applies to:
SYMPTOMSWhen running Microsoft Windows in 386 enhanced mode in conjunction with the DFI's scanner program (SCAN.EXE) that comes with the DFI HS 3000 Plus Scanner, you may get the following error message:
CAUSEThe DmaBufferSize line may need to be added in the [386Enh] section of the SYSTEM.INI file so that the DFI scanner program can run. RESOLUTION
To make the adjustment:
MORE INFORMATION
DMABufferSize specifies the amount of memory (in kilobytes) to be reserved
for buffered direct memory access (DMA). This memory is allocated above
640K, if possible. Windows in 386 enhanced mode defaults to a DMA buffer
size that handles disk access. The default setting size is 16. To change
the value, add the line above to the [386Enh] section.
REFERENCESSYSINI2.TXT Additional query words: 3.00 3.00a 3.10 3.11 3rdparty KBHW scan