DCA Irma Workstation for Windows and PCLP Network
ID: Q82400
|
The information in this article applies to:
-
Microsoft Windows versions 3.1, 3.11
SYMPTOMS
The following information applies to Microsoft Windows running in enhanced
mode.
When a DCA Irma Workstation for Windows is run using NETBIOS to connect to
the IRMALAN gateway using PCLP version 1.34, the system stops responding
(hangs) shortly after a NETBIOS connection is made.
CAUSE
This is not a problem with the MS-DOS based version of DCA IRMA
Workstation.
This is not a problem with Windows, but with the applications use of
page-locked memory.
WORKAROUND
Run Windows in standard mode or add more memory to the system.
The product included here is manufactured by a vendor independent of
Microsoft; we make no warranty, implied or otherwise, regarding this
product's performance or reliability.
Additional query words:
3.10 3.1 3.11
Keywords :
Version : WINDOWS:3.1,3.11
Platform : WINDOWS
Issue type :