EGA.SYS Doesn't Load for Windows 3.1

ID: Q82456


The information in this article applies to:
  • Microsoft Windows versions 3.1, 3.11


SYMPTOMS

When you use the MS-DOS SETUP /N command to install a shared copy of Microsoft Windows to a network drive on a machine with an EGA monitor, Setup adds the following line to the CONFIG.SYS file


   DEVICE=X:\WINPATH\EGA.SYS 
where X is the net drive.

As a result, when you boot the machine, EGA.SYS doesn't get loaded because the network has not started yet.


RESOLUTION

To correct this, copy EGA.SYS from the net drive to the local hard disk, floppy boot disk, or remote boot area on the network and modify the CONFIG.SYS file.

Additional query words: 3.10 3.1 EGA.SYS 3.11 SETUP/N

Keywords :
Version : WINDOWS:3.1,3.11
Platform : WINDOWS
Issue type :


Last Reviewed: October 29, 1999