UltraStor 22CA ESDI Controller Needs /Double_Buffer+ Line

ID: Q83702


The information in this article applies to:
  • Microsoft Windows versions 3.1, 3.11


SYMPTOMS

When you use an UltraStor 22CA ESDI hard drive controller with version 1.02 or earlier of the UltraStor Virtual DMA Services (VDS) driver UVDS.SYS, Microsoft Windows version 3.1 may return to the MS-DOS command prompt when you start Windows in 386 enhanced mode.


WORKAROUND

To correct this problem, do the following:

  1. Edit the CONFIG.SYS file with a standard ASCII text editor.


  2. Add the following line:
    device=c:\windows\smartdrv.exe /double_buffer+


NOTE: You do not need to modify the existing SMARTDRV.EXE entry in the AUTOEXEC.BAT file.


MORE INFORMATION

Some ESDI hard drives require the VIRTUALHDIRQ=OFF line in the [386enh] section of the SYSTEM.INI file. To test if this line is needed in Windows 3.1, start Windows with the following command:

win /d:v
If Windows starts successfully, the VIRTUALHDIRQ=OFF line is necessary.

The 22CA ESDI hard drive controller is manufactured by UltraStor, a vendor independent of Microsoft; we make no warranty, implied or otherwise, regarding this product's performance or reliability.

Additional query words: 3.10 "Error Loading GDI.EXE"

Keywords :
Version : WINDOWS:3.1,3.11
Platform : WINDOWS
Issue type :


Last Reviewed: October 1, 1999
© 2000 Microsoft Corporation. All rights reserved. Terms of Use.