Startup Directory Doesn't Work in Standard on Novell

ID: Q84905


The information in this article applies to:
  • Microsoft Windows versions 3.1, 3.11


SYMPTOMS

When running MS-DOS applications in Microsoft Windows version 3.1 in standard mode on a Novell network, the Working Directory setting in the Program Item Properties dialog box, and the Start-up Directory setting in a PIF do not function if the directory specified is a network drive (not the local hard drive). This problem does not occur in 386 enhanced mode.


STATUS

Microsoft has confirmed this to be a problem in Windows version 3.1. We are researching this problem and will post new information here as it becomes available.


WORKAROUND

To work around this problem

  1. Create a batch file (for example, APP.BAT) that changes to the desired directory, and then starts the MS-DOS application (for example, MYAPP.EXE).
    
          CD\ 
          U:
          CD\DATA
          C:\MYDIR\MYAPP.EXE 


  2. Do one of the following:

    1. Change the PIF's Program Filename to APP.BAT:
      
               Program Filename:       APP.BAT
               Windows Title:          MyApp
               Optional Parameters:
               Start-up Directory: 
      -or-


    2. Modify the command line for the icon's properties to APP.BAT:
      
               Description:            MyApp
               Command Line:           APP.BAT
               Working Directory:
               Shortcut Key: 




Additional query words: 3.10 3.11 3rdparty